Typically, the mechanical behavior of CLT shear walls for lateral loads is assumed to be governed by the wall base connections such as hold-downs and angle brackets. However, in a “box type” construction typology of CLT buildings, the connections between perpendicular walls contribute to the lateral response of the CLT shear walls. This study presents the results of an experimental campaign aimed at investigating the lateral performance of CLT shear walls connected to perpendicular walls. Two CLT wall assembly configurations were tested: single Shear Wall configuration (SW), which considers a single CLT shear wall subjected to lateral load and Shear Wall connected to Perpendicular Wall configuration, which considers a CLT Shear Wall subjected to lateral load connected to a Perpendicular Wall (SW+PW). Results showed that the Shear Wall connected to a Perpendicular Wall configuration reached higher structural performance in terms of lateral stiffness and lateral capacity than single Shear Wall configuration. This increase of lateral performances is governed by the properties of the wall-to-wall connections as well as the properties of the hold downs used in the perpendicular walls. Results of this experimental study show that the perpendicular walls and wall-to-wall connections can be included in the design models of CLT shear walls subjected to lateral loads.

Experimental investigation on the lateral performance of CLT shear walls connected to perpendicular walls

Ruggeri, Elisabetta Maria;Li Cavoli, Denise;Cottonaro, Rosario Davide;Fossetti, Marinella
2022-01-01

Abstract

Typically, the mechanical behavior of CLT shear walls for lateral loads is assumed to be governed by the wall base connections such as hold-downs and angle brackets. However, in a “box type” construction typology of CLT buildings, the connections between perpendicular walls contribute to the lateral response of the CLT shear walls. This study presents the results of an experimental campaign aimed at investigating the lateral performance of CLT shear walls connected to perpendicular walls. Two CLT wall assembly configurations were tested: single Shear Wall configuration (SW), which considers a single CLT shear wall subjected to lateral load and Shear Wall connected to Perpendicular Wall configuration, which considers a CLT Shear Wall subjected to lateral load connected to a Perpendicular Wall (SW+PW). Results showed that the Shear Wall connected to a Perpendicular Wall configuration reached higher structural performance in terms of lateral stiffness and lateral capacity than single Shear Wall configuration. This increase of lateral performances is governed by the properties of the wall-to-wall connections as well as the properties of the hold downs used in the perpendicular walls. Results of this experimental study show that the perpendicular walls and wall-to-wall connections can be included in the design models of CLT shear walls subjected to lateral loads.
2022
9781713870418
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11387/158934
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact