BACKGROUND: Restrictive mitral annuloplasty (RMA) can be an effective treatment for functional mitral regurgitation in congestive heart failure (CHF). Passive cardiac restraint is another surgical approach, but the midterm results are not well characterized. METHODS: Thirty patients with functional mitral regurgitation were prospectively randomized to RMA alone or cardiac restraint with the CorCap Cardiac Support Device (Acorn Cardiovascular Inc, St. Paul, MN) and RMA. Clinical, echocardiographic, New York Heart Association (NYHA) functional class, Short Form 36-Item Health Survey (SF-36) quality of life scores, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) results were analyzed. RESULTS: No hospital deaths or device-related complications occurred. The two groups had comparable morbidity (p = 0.34). Echocardiography showed a trend towards a slightly better functional improvement during follow-up in CorCap plus RMA patients (between groups, p = 0.001). Both groups showed improved results for SF-36, NYHA, and NT-pro.BNP; however, CorCap plus RMA patients had significantly better SF-36 at discharge (p = 0.003), postoperative NYHA (p = 0.05), and NT-pro.BNP (p = 0.001). Survival (p = 0.46), freedom from CHF (p = 0.23), and rehospitalization (p = 0.28) were comparable. Patients in whom CHF developed after postoperative day 1 had higher NT-pro.BNP values (p = 0.001 at all time-points). CONCLUSIONS: Adjunctive application of CorCap with RMA correlated with better NT-pro.BNP at short-term follow-up together with slightly improved echocardiographic and functional results. This deserves further evaluation at midterm and long-term follow-up. Reduction of NT-pro.BNP at follow-up may be suggested as a prognostic index.
Neurohormonal and echocardiographic results after CorCap and mitral annuloplasty for dilated cardiomyopathy
Rubino AS
Writing – Original Draft Preparation
;
2009-01-01
Abstract
BACKGROUND: Restrictive mitral annuloplasty (RMA) can be an effective treatment for functional mitral regurgitation in congestive heart failure (CHF). Passive cardiac restraint is another surgical approach, but the midterm results are not well characterized. METHODS: Thirty patients with functional mitral regurgitation were prospectively randomized to RMA alone or cardiac restraint with the CorCap Cardiac Support Device (Acorn Cardiovascular Inc, St. Paul, MN) and RMA. Clinical, echocardiographic, New York Heart Association (NYHA) functional class, Short Form 36-Item Health Survey (SF-36) quality of life scores, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) results were analyzed. RESULTS: No hospital deaths or device-related complications occurred. The two groups had comparable morbidity (p = 0.34). Echocardiography showed a trend towards a slightly better functional improvement during follow-up in CorCap plus RMA patients (between groups, p = 0.001). Both groups showed improved results for SF-36, NYHA, and NT-pro.BNP; however, CorCap plus RMA patients had significantly better SF-36 at discharge (p = 0.003), postoperative NYHA (p = 0.05), and NT-pro.BNP (p = 0.001). Survival (p = 0.46), freedom from CHF (p = 0.23), and rehospitalization (p = 0.28) were comparable. Patients in whom CHF developed after postoperative day 1 had higher NT-pro.BNP values (p = 0.001 at all time-points). CONCLUSIONS: Adjunctive application of CorCap with RMA correlated with better NT-pro.BNP at short-term follow-up together with slightly improved echocardiographic and functional results. This deserves further evaluation at midterm and long-term follow-up. Reduction of NT-pro.BNP at follow-up may be suggested as a prognostic index.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.