Seismic liquefaction is one of the most devastating natural hazards that can cause significant damage to structures and infrastructure. The liquefaction behaviour is simulated in the finite element code PLAXIS by the UBC3D-PLM constitutive model that is 3-D generalized formulation of the 2-D UBCSAND model developed at the University of British Colombia. The UBC3D-PLM model used in this work was successfully employed in many recent studies, e.g. to evaluate the liquefaction effects on the seismic soil–structure interaction, to assess the dynamic behaviour of earthen embankments built on liquefiable soil and to investigate the seismic performance of offshore foundations. Moreover, UBC3D-PLM model involves many input parameters to model the onset of the liquefaction phenomenon. Therefore, their determination becomes a crucial concern. Previous studies elaborated a specific formulation that requires the corrected Standard Penetration Test (SPT) blow counts as input. However, the Dilatometer Marchetti Test (DMT), compared to the SPT, is more sensitive to several factors that affect the liquefaction resistance such as aging, stress history, overconsolidation and horizontal earth pressure. For this reason, a new parameter selection procedure, which uses the horizontal stress index derived from DMT, was developed in this study. The new relationships were applied for determining the initial parameters of the UBC3D-PLM model to describe the behavior of several liquefiable deposits located in eastern Sicily (Italy) that experienced destructive earthquakes in the past. For each site, the model was calibrated to the DMT-based liquefaction triggering curve, developed by combining DMT correlations with the current method based on SPT test, by the simulation of cyclic direct simple shear tests (CDSS). Finally, CDSS tests were performed by means of the CDSS device at the Soil Dynamics and Geotechnical Engineering Laboratory of the University “Kore” of Enna (Italy). This allowed to validate the applicability of the proposed procedure in simulating the liquefaction behavior of sandy soils.

Calibration of the UBC3D-PLM soil model from Dilatometer Marchetti Test (DMT) for the liquefaction behaviour and cyclic resistance ratio (CRR) of sandy soils

Castelli F.;Lentini V.
;
Sammito M. S. V.
2024-01-01

Abstract

Seismic liquefaction is one of the most devastating natural hazards that can cause significant damage to structures and infrastructure. The liquefaction behaviour is simulated in the finite element code PLAXIS by the UBC3D-PLM constitutive model that is 3-D generalized formulation of the 2-D UBCSAND model developed at the University of British Colombia. The UBC3D-PLM model used in this work was successfully employed in many recent studies, e.g. to evaluate the liquefaction effects on the seismic soil–structure interaction, to assess the dynamic behaviour of earthen embankments built on liquefiable soil and to investigate the seismic performance of offshore foundations. Moreover, UBC3D-PLM model involves many input parameters to model the onset of the liquefaction phenomenon. Therefore, their determination becomes a crucial concern. Previous studies elaborated a specific formulation that requires the corrected Standard Penetration Test (SPT) blow counts as input. However, the Dilatometer Marchetti Test (DMT), compared to the SPT, is more sensitive to several factors that affect the liquefaction resistance such as aging, stress history, overconsolidation and horizontal earth pressure. For this reason, a new parameter selection procedure, which uses the horizontal stress index derived from DMT, was developed in this study. The new relationships were applied for determining the initial parameters of the UBC3D-PLM model to describe the behavior of several liquefiable deposits located in eastern Sicily (Italy) that experienced destructive earthquakes in the past. For each site, the model was calibrated to the DMT-based liquefaction triggering curve, developed by combining DMT correlations with the current method based on SPT test, by the simulation of cyclic direct simple shear tests (CDSS). Finally, CDSS tests were performed by means of the CDSS device at the Soil Dynamics and Geotechnical Engineering Laboratory of the University “Kore” of Enna (Italy). This allowed to validate the applicability of the proposed procedure in simulating the liquefaction behavior of sandy soils.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11387/180865
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact