Three-dimensional multiplanar reconstruction was used to diagnose recurrence of mitral regurgitation after MitraClip implantation in a 71-year-old man. Subsequent mitral valve surgery in such a case is high risk, and repeat MitraClip intervention could be feasible but is technically challenging. This imaging series demonstrates that LVAD implantation may be a solution to address MitraClip failure.
Loss of Leaflet Insertion After Percutaneous Mitral Valve Repair Requiring Left Ventricular Assist Device Implantation: Usefulness of 3D Multiplanar Reconstruction
Pappalardo, Federico;
2019-01-01
Abstract
Three-dimensional multiplanar reconstruction was used to diagnose recurrence of mitral regurgitation after MitraClip implantation in a 71-year-old man. Subsequent mitral valve surgery in such a case is high risk, and repeat MitraClip intervention could be feasible but is technically challenging. This imaging series demonstrates that LVAD implantation may be a solution to address MitraClip failure.File in questo prodotto: