Background: To show a novel modified technique to perform minimally invasive anterior odontoid screw fixation. Methods: Twenty-nine patients with a mean age of 45 years were treated with a modified percutaneous anterior odontoid screw fixation. All patients were affected by Type II or rostral shallow Type III odontoid fractures. A modified guide tube was used in all these patients, with reduction of soft tissue dissection for percutaneous approach. Results: There were no complications related to the modified technique. Good results and optimal screw placement were achieved in 28 out of 29 patients. Only in 1 patient we observed, after mobilization, screw displacement, probably due to severe osteoporosis. Conclusions: In our opinion, this modified percutaneous minimally invasive technique for anterior odontoid screw fixation, along with the use of a soft tissue dilator not fixed to the spine, has not yet been reported in literature and is strongly recommended to reduce invasiveness of odontoid screw placement.

Minimally invasive percutaneous anterior odontoid screw fixation: institutional experience with a simple and effective technique

Umana G;
2020-01-01

Abstract

Background: To show a novel modified technique to perform minimally invasive anterior odontoid screw fixation. Methods: Twenty-nine patients with a mean age of 45 years were treated with a modified percutaneous anterior odontoid screw fixation. All patients were affected by Type II or rostral shallow Type III odontoid fractures. A modified guide tube was used in all these patients, with reduction of soft tissue dissection for percutaneous approach. Results: There were no complications related to the modified technique. Good results and optimal screw placement were achieved in 28 out of 29 patients. Only in 1 patient we observed, after mobilization, screw displacement, probably due to severe osteoporosis. Conclusions: In our opinion, this modified percutaneous minimally invasive technique for anterior odontoid screw fixation, along with the use of a soft tissue dilator not fixed to the spine, has not yet been reported in literature and is strongly recommended to reduce invasiveness of odontoid screw placement.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11387/187857
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
social impact