Introduction: This preliminary in vitro study aims to evaluate the application of micro-CT in analyzing the microstructural coupling between dental implant fixtures and prosthetic abutments, with an emphasis on understanding the effectiveness and limitations of this technique in dental implantology. Materials and Methods: A search of PubMed, MEDLINE, and the Cochrane Library up to May 2024 identified eight relevant studies that examined different facets of dental implantology, such as osseointegration, implant stability, and the comparative accuracy of micro-CT versus other imaging techniques. A comparative micro-CT radiographic analysis was performed on five different implant fixtures with respective prosthetic and healing abutments, by using SkyScan1174 micro-CT. Results: The reviewed studies demonstrated that micro-CT is reliable for assessing bone quality, implant stability, and the microstructural integrity of dental implants. Micro-computed tomography (micro-CT) studies reveal bone-implant contact (BIC) ratios of 40-80%, bone volume per total volume (BV/TV) values of 20-60%, and detect microgaps as small as 0.3 mu m, highlighting its high-resolution capability (5-10 mu m) for detailed implant analysis. The comparative analysis of the implant fixtures analyzed the implant-abutment connection, highlighting the relevance of implant design for ensuring stability. Conclusions: Micro-CT analysis has proven to be a valuable tool for evaluating the intricate microstructural properties of dental implants, offering insights into implant stability, bone quality, and osseointegration. The literature reviewed highlights consistent findings that underscore micro-CT's accuracy and reliability in capturing high-resolution data, suggesting its potential as a standard imaging modality in implant research and clinical assessment.
Micro-CT Structure Analysis on Dental Implants: Preliminary In Vitro Trial
Fiorillo L.;
2024-01-01
Abstract
Introduction: This preliminary in vitro study aims to evaluate the application of micro-CT in analyzing the microstructural coupling between dental implant fixtures and prosthetic abutments, with an emphasis on understanding the effectiveness and limitations of this technique in dental implantology. Materials and Methods: A search of PubMed, MEDLINE, and the Cochrane Library up to May 2024 identified eight relevant studies that examined different facets of dental implantology, such as osseointegration, implant stability, and the comparative accuracy of micro-CT versus other imaging techniques. A comparative micro-CT radiographic analysis was performed on five different implant fixtures with respective prosthetic and healing abutments, by using SkyScan1174 micro-CT. Results: The reviewed studies demonstrated that micro-CT is reliable for assessing bone quality, implant stability, and the microstructural integrity of dental implants. Micro-computed tomography (micro-CT) studies reveal bone-implant contact (BIC) ratios of 40-80%, bone volume per total volume (BV/TV) values of 20-60%, and detect microgaps as small as 0.3 mu m, highlighting its high-resolution capability (5-10 mu m) for detailed implant analysis. The comparative analysis of the implant fixtures analyzed the implant-abutment connection, highlighting the relevance of implant design for ensuring stability. Conclusions: Micro-CT analysis has proven to be a valuable tool for evaluating the intricate microstructural properties of dental implants, offering insights into implant stability, bone quality, and osseointegration. The literature reviewed highlights consistent findings that underscore micro-CT's accuracy and reliability in capturing high-resolution data, suggesting its potential as a standard imaging modality in implant research and clinical assessment.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


